Latest Blog Posts Latest Blog Posts


Tweet
 
Like

window CE MARK

We are CE marked on both windows and doors

RESIDENTIAL DOORS CE MARK WINDOW CE MARK

 What is the window CE mark?
The CE mark is required for all new window products which are subject to one or more of the European product safety Directives. It is a  sign that the manufacturer of the product is declaring conformity with all of the EU Directives relating to that product. We at u-fit have CE marking prior to it becoming a legal requirement on July 1st 2013.

When is the CE mark required?
Products placed on the European market must be CE marked. This will include products which are "new" to Europe, that is second-hand products from outside Europe and which are put into service or placed on the market in Europe for the first time, and existing products which are so substantially modified as to be considered


Who should undertake window CE marking?
Window CE marking is the responsibility of the person who fits the product on the market, or manufactures the window, for the first time. In law this duty rests with the Responsible Person, which in most cases is either the window fabricator.Or If you are a window installer and by your glass and windows from two different suppliers you must undergo CE marking yourself.


What does the window CE mark mean?
<p>By affixing the CE mark the Responsible Person takes on responsibility for the conformity of the product. CE marking is a visible sign that the product complies with all relevant product supply law, and its presence together with the Declaration of Conformity gives the product to which it is affixed presumption of conformity with relevant product safety Directives. CE marked products are entitled to free movement throughout the European market (EU and EEA). However, the CE mark is not a quality mark, nor a guarantee that the product meets all of the requirements of relevant EU product safety law. 

U-FIT CE MARKING LABEL REFERENCE NUMBER 0613-W U-FIT Heritage works Unit 1, Boston Place Coventry CV6 5NN 13 BS EN14351-1:2006 + A1:2010 - 002 Casement Window Intended to be used in Domestic and Commercial Locations.</strong> Dangerous substances &ndash; None Load bearing capacity of safety devices &ndash;Pass Thermal Performance &ndash; 1.7 W/(m2 K) </p>

U-FIT CE MARKING LABEL REFERENCE NUMBER 0613-D U-FIT Heritage works Unit 1, Boston Place Coventry CV6 5NN 13 BS EN14351-1:2006 + A1:2010 - 003 Residential Door Intended to be used in Domestic and Commercial Locations.</strong> Dangerous substances &ndash; None Load bearing capacity of safety devices &ndash;Pass Thermal Performance &ndash; 1.6 W/(m2 K) </p>

EC DECLARATION OF PERFORMANCE (System 3) Issue No: 002 U-FIT Heritage works Unit 1, Boston Place Coventry CV6 5NN This document declares that the product: Casement windows Pvc-u For domestic and commercial buildings,</strong> conforming to the product requirements of BS EN 14351-1:2006+A1:2010 Annex ZA Essential Characteristics Performance Test Standards Name, Address and Notified Body No of Test Laboratory Test report reference and issue date 

Watertightness NPD BS EN 1027 N/A N/A Dangerous substances NONE BS EN 14351-1: 2006+A1:2010 N/A Safety Data Sheet Resistance to wind load NPD BS EN 12211 N/A N/A Load-bearing capacity of safety devices PASSED BS EN 948 BUILDCHECK 1806 W13022-2 4 February 2013 Acoustic performance NPD BS EN ISO 140-3 N/A N/A Thermal transmittance 1.7W(m2k) EN ISO 10077-1 &amp; EN ISO 10077-2 (or EN ISO 12567-1 and EN 12567-2) Buildcheck 1806 Synseal window A4.9 6 June 2013 Radiation properties NPD EN 410 N/A N/A Air permeability NPD BS EN 1026 N/A N/A Signed on behalf of U-FIT Windows Limited: Signature: ;A Richards General Manager. Date 6 June 2013</
EC DECLARATION OF PERFORMANCE (System 3) Issue No: 003 U-fit Heritage Works Unit 1 Boston Place Coventry CV6 5NN This document declares that the product: Residential doors System Description: For domestic and commercial buildings</strong>, conforming to the product requirements ofBS EN 14351-1:2006+A1:2010Annex ZA Essential Characteristics Performance Test Standards Name, Address and Notified Body No of Test Laboratory Test report reference and issue date.

;Watertightness NPD BS EN 1027 N/A N/A Dangerous substances NONE BS EN 14351-1: 2006+A1:2010 N/A N/A Resistance to wind load NPD BS EN 12211 N/A N/A Impact resistance BS EN 13049 Load-bearing capacity of safety devices BS EN 948 Height (mm) BS EN 14351-1: 2006+A1:2010 N/A N/A Ability to release PASSED BS EN 179 and BS EN 1125 MILA - 0425 0529-CPD-2009 Acoustic performance NPD BS EN ISO 140-3 N/A N/A Thermal transmittance 1.6W(m2K) EN ISO 10077-1 &amp; EN ISO 10077-2 (or EN ISO 12567-1 and prEN 12567-2) BIULDCHECK 003 5 JUNE 2013 Radiation properties NPD EN 410 N/A N/A Air permeability NPD BS EN 1026 N/A N/A